Special Order Item: Y

NOVAFIL™ Monofilament Polybutester Sutures, 2-0, CE-6/C-14 Needle

SKU: 8354422-53

Status: Out of Stock

Box 12 (1)
Call For Price

 

NOVAFIL™ Monofilament Polybutester Sutures

NOVAFIL™ nonabsorbable monofilament surgical sutures are composed of polybutester, a copolymer of butylene terephthalate and polytetramethylene ether glycol.

The unique properties of NOVAFIL™ monofilament sutures are attributed to the composition and structure of the polybutester fiber which give the suture:

  • Suppleness and easy handling
  • Unique elasticity and flexibility  
  • Excellent knot security
  • Less tissue drag and smooth knot run-down
  • Fray resistance
  • Unique resistance to creep and structural fatigue 

Novafil™ polybutester sutures are indicated for use in general soft tissue approximation and/or ligation, including use in cardiovascular and ophthalmic surgery, but not in microsurgery and neural tissue.

  • Needle Type - Reverse Cutting
  • Curvature - 3/8 Circle
  • Needle Length - 24mm
  • Length - 18"
  • Needle Name - C-14
  • Color - Blue

 

More Info

More Info

Suture Substances

  • Phthalates Free
  • PVC Free
  • Bisfenol Free
  • Antimicrobial Substances Free
  • Latex Free
  • Triclosan Free*

* Medtronic sutures are 100% triclosan free

Product Information

Structure

monofilament

Suture Type

non-absorbable

Composition

polybutester

Coating

uncoated

Color

blue and clear

Tensile Strength

permanent

Absorption Profile

permanent

Sizes

7–0 to 2

Indications

Novafil™ polybutester sutures are indicated for use in general soft tissue approximation and/or ligation, including use in cardiovascular and ophthalmic surgery, but not in microsurgery and neural tissue.

Contradictions

The use of this suture is contraindicated in patients with known sensitivities or allergies to its components.

Sterilization Method

gamma irradiation

CE Marked

class III according to EU directive 93/42/EEC, annex II

Box Quantities

1 or 3 dozen

Shelf Life

5 years

Temperature and Humidity Levels

Currently, the IFU for Medtronic Legacy Covidien SI Suture devices state to store at room temperature. In general, stability studies are performed with short term exposure to either 50 degrees (38 weeks) or 54.4 degrees (32 weeks) for accelerated aging testing purposes only. This condition is not intended for storage purposes. Real time testing is performed at 22 degrees +/- 10 degrees with uncontrolled humidity for the entirety of the device shelf-life.

 